Hybrid Inverter WD8-SP
- Multi-setting
- PV priority mode or AC priority mode
- Choose the charging current based on the configured capacity of the battery
- High reliability: Double MCU digital control
- Independent MPPT (Maximum Power Point Tracking) control microprocessor system
- Independent inverter microprocessor control system
- Isolated and pure sine wave technology
- LCD + LED display
- Wide input range
- High-speed synchronous conversion
- Friendly alarm system
- Online protection function
- Frequency auto adaptive
- Intelligent No-load auto shutdown technology (optional)
- Intelligent minitoring (RS232, USB, or SNMP card, optional)
Inverter Specification |
||||||||
Power |
8KW |
|||||||
Battery voltage |
192Vdc |
|||||||
Working mode |
PV priority/AC priority optional |
|||||||
PV |
|
|||||||
MPPT voltage range |
192Vdc-400Vdc |
|||||||
Max. charge current |
10-60A |
|||||||
PV panels configuration (Suggestion)(Vmp) |
240-284Vdc |
|||||||
PV panels configuration (Suggestion)(Imp) |
≤60A | |||||||
Conversion efficiency |
≥98% | |||||||
Display |
||||||||
Panel indicator |
LCD+LED Panel display |
|||||||
AC mode |
|
|||||||
Input voltage range |
165Vac-275Vac |
|||||||
Input frequency range |
40-70Hz (auto transfer to battery mode. If beyond this range) |
|||||||
Output voltage precision |
220Vac± 5% |
|||||||
Input power factor |
≥0.8 | |||||||
Max. efficiency |
88% (inverter on) |
|||||||
Overload |
110% transfer to bypass in 255s. 120% go to bypass in 60s. 150% go to bypass in 10s. |
|||||||
Max. charging current |
12A |
|||||||
Short circuit protection |
Electronic limited current output or turn bypass, air breaker protection |
|||||||
Inverter mode |
|
|||||||
Output voltage |
220Vac± 5% |
|||||||
Output frequency |
50Hz/60Hz ± 1% Frequency self-adjusted |
|||||||
Output power factor |
1 | |||||||
Distortion |
<5% Linear load |
|||||||
PC-AC transfer time |
0ms |
|||||||
Max. efficiency |
≥92% | |||||||
Overload |
110% transfer to bypass, in 255s or shutdown, 120% go to bypass or shutdown in 60s, 150% go to bypass or shutdown in 10s |
|||||||
Eco Mode (Optional) |
When Load <5%, system will turn to bypass power supply (utility) in 1min |
|||||||
Short circuit |
Electronic limited current output, turn the bypass or system to be automatic shutdown |
|||||||
Alarm |
|
|||||||
AC fails |
1/4 automatic sound elimination after 40s | |||||||
Battery low voltage |
5/1s | |||||||
Overload |
1/1s | |||||||
Communication (Optional) |
|
|||||||
Communication interface |
RS232/USB/RS485/SNMP |
|||||||
Dry contact |
PV failure, battery low voltage, overload, bypass, inverter failure, remote start generator dry contact signal |
|||||||
Others |
|
|||||||
Output connection |
Terminal blocks |
|||||||
Surge protection |
Optional | |||||||
EMC |
Accord with EN62040-2:EN61000-3-2-2006:EN61000-3-3:2008 |
|||||||
IP class |
IP20 |
|||||||
Ambient temperature |
0°C – 40°C |
|||||||
Ambient humidity |
10% – 90% (Non Condensed) |
|||||||
Noise |
≤50dB | |||||||
Working attitude |
2000m (Every 100m increase derating 1%) |
|||||||
Dimension (WxDxH)mm |
560x265x725 |
|||||||
Packing dimension (WxDxH)mm |
662x360x905 | |||||||
Weight |
85 |
|||||||
Packing Weight |
94 |